MNGL New Connection Application : Maharashtra Natural Gas
Organisation : Maharashtra Natural Gas Limited (MNGL)
Facility Name : MNGL New Connection Application
Applicable State/UT : Maharashtra
Website : https://mngl.in/
Want to ask a question / comment on this post? Go to bottom of this page. |
---|
How To Apply For MNGL New Connection?
To apply for MNGL Gas New Connection, follow the below steps
Related / Similar Facility : MNGL Bill Online Payment
Steps:
** Applicant residing in a particular building should have a gas supply
** Payments can be made through online transaction only.
** As per safety standards, in case, the applicant’s residence is found to be technically not feasible, MNGL will refund the amount paid by the applicant in full.
** Applicant should be the owner of the flat for which new connection is requested. Incase of any dispute w.r.t. ownership arising in future, the security deposit against the connection stands forfeited.
** Online Scheme1 not applicable to those customers who have surrender the connection before the installment plan.
Apply Here : https://mngl.in/apply-new-connection
Technical Guidelines For PNG Installation
Meter Position:
** Gas Meters will normally be located inside the property on wall, and use of copper pipe between MCV and consumer meter should be restricted as far as possible. The Kitchen is the preferred room to locate the meter thereby minimizing the length of the outlet pipe – work.
** The meter shall be installed in an area with adequate ventilation & Gas pipeline not to be concealed
** As a guide, a minimum ventilation area of 2°/o of the internal floor area of the room must be provided in the room where the meter is located. The gaps under and around doors, windows and ventilators provide adequate ventilation to the rooms of normally occupied individual domestic dwellings.
** Space near Meter installation & pipeline should not used for storage of any cleaning chemicals, harsh chemicals, rubbish or any other material prone to create any safety hazard to the meter/ pipeline and I or blocking ventilation.
** Meters must not be installed along a route that is used by more than one property as a means of a fire escape-i.e., a communal fire escape route.
** The meter shall be installed at a proper location and height, so as to facilitate safe and convenient meter reading and maintenance activities in future.
** Appliance Valve shall be fitted at least 100 mm above the kitchen platform level and at an easily accessible location.
** Steel reinforced rubber hose is connected between AV and Appliance Length of flexible hose shall be kept minimum.
Pipe work in Island type Kitchen:
** In some of the residences, kitchen platform is located incenter of the room and pipe work requires extending from MCV & meter (mounted on one of the wall) up to the appliance valve. Under such circumstances, pipe can be laid in flooring with adequate protection.
** Pipe work passing through flooring should take the shortest practicable route and must be sleeved.
** Pipe work laid in flooring shall be protected against corrosion and also against failure caused by movement.
** Pipes should be laid on the base concrete and avoid joints in the pipe section. A minimum of 65 mm screed is required on top of the concrete which will provide an approximate cover of 50 mm over a 12 mm installation pipe.
** In case of screeded floors, the method of construction consists of a base concrete raft foundation onto which a cement screed is subsequently laid in order to obtain a satisfactory surface to accept the floor finish.
** In this case, copper pipes may be laid on top of the base concrete and subsequently covered by the screed, provided the pipe is protected from corrosion. Alternatively, the copper pipes may be laid through pre-formed PVC I HOPE sleeves I ducts with protective covers
Gas geysers Location:
Gas Geysers should only be installed in areas like:
** Kitchens, Living rooms, Utility Rooms, Halls and Passageways if flueing and ventilation can be achieved.
** Gas Geyser should be installed at such a height that it can be switched off easily.
** No Gas Geyser is permitted to be concealed
Contact
Call : 1800 266 2696
Emergency Helpline : 9011 676767
Email : customercare@mngl.in